20A-350A Contactor
12V-350V Contactor
DC or 50/60 Hz AC Contactor
15" Leads

Part Number ECPC-350
20A-350A Contactor <br> 12V-350V Contactor <br> DC or 50/60 Hz AC Contactor <br> 15
20A, 30A, 50A, 75A, 100A, 125A, 150A, 225A, 350A Contactor 12V, 24V, 48V, 72V, 120V, 350V
Email a friend Email a friend
Price
Your Price:  
$98.00
Free Shipping
Choose Options
Model
Quantity Price
1+ $98.00
Quantity
Add to Gift Registry
Description


 
EPIC® Hermetic Sealed DC and AC Contactor - 350+ Amp Power Switching
RoHS Compliant, all date codes
 
 
Contactor Features
Rugged EPIC® Ceramic-to-Metal Seal Rated to 175°C – Reduced risk of fire or meltdown in over-current conditions compared to the less-durable epoxy seal.
EPIC® Hermetic Seal – Designed to meet UL1604 for Class I & II, Div 2 and Class III for use in hazardous locations, IP67 for temporary water immersion for 30 min, SAE J1171 - external ignition protection, and ISO8846 for protection against ignition around flammable gasses.
High Efficiency Dual Coils ? Unlike the PWM coil economizer found in other contactors that can cause cross-talk on your system control power or radiate noise, the Contactor uses two coils. One drops out after the contactor is energized providing low power to keep the contactor energized.
No Exposed Coil Electronics ? The Contactor can operate almost anywhere, even under water - unlike other contactors with exposed PWM coil electronics that can fail in harsh environments.
Built-in Power Terminal Safety Cover ? Extra assurance of a safer connection without the use of metal fastening screws. Can also be easily permanently removed in applications where not needed.
Fully RoHS Compliant ? It is fully compliant and is better for the environment and future generations.
Built-in coil suppression ? Saves you THE engineering time and parts cost to add external coil suppression.
Clear & Precise Specifications – No guessing to see if the contactor will work in your application.
             
       
UL Compliant DC & AC Estimated Contact Power Switching Ratings

Make & Break Resistive Current
with 400 KCmil cable and 50°
terminal temp rise

Contact Voltages & Life Cycle Ratings
DC or 50/60 Hz AC
24 V 48 V 72 V 120 V 350 V
 350A - (75° C Ambient) 1/ 75,000 56,250 26,250 15,000 3,000
 225A - (75° C Ambient) 1/ 100,000 75,000 35,000 20,000 4,000
 150A - (75° C Ambient) 1/ 120,000 90,000 42,000 24,000 4,800
 125A - (75° C Ambient) 1/ 150,000 112,500 52,500 30,000 6,000
 100A - (75° C Ambient) 1/ 200,000 150,000 70,000 40,000 8,000
 75A - (75° C Ambient) 1/ 290,000 217,500 101,500 58,000 11,600
 50A - (75° C Ambient) 1/ 500,000 375,000 175,000 100,000 20,000
 30A - (75° C Ambient) 1/ 600,000 450,000 210,000 120,000 24,000
 20A - (75° C Ambient) 1/ 700,000 525,000 245,000 140,000 28,000
 400A - (50° C Ambient) 2/ 60,000 45,000 21,000 12,000 2,400
 Max Break A, 2 cycles
 (75° C Ambient) 1/
3,900A 3,600A 2,900A 2,200A 1,980A
 Max Make, 10 cycles
 (75° C Ambient) 1/
1,000A 900A 800A 700A 600A

Electrical life rating is based on resistive load with 27µH maximum inductance in circuit. Because your application may be different, we suggest you test the contactor in your circuit to verify life is as required.
 
End of life is defined as when the dielectric, insulation resistance or contact resistance exceeds the specifications listed.
  
1/ Assumes UL508 ratings with 400 KCmil cables, UL508 max ambient temperature of 75°C as shown, and max. UL508 terminal temperature rise of 50°C. For less than 100A, standard UL recommended cable sizes are assumed.
 
At 85°C ambient, contactor can also meet all of its 75°C specifications but the terminal temperature can rise can be up to 60°C, which is higher than the 50°C rise allowed by UL508 and can be higher than some cable insulation ratings.

 
2/ Assumes UL508 ratings with 400 KCmil cables, at a lower 50°C UL508 ambient temperature, and max. UL508 terminal temperature rise of 50°C.
 
  
UL Compliant DC & AC Contact Current Carry Ratings
    75°C / 50°C
 Cable size 1/ KCmil 400
 Continuous, UL508 Max 1/
     10 seconds (1 time)
     100 Seconds (1 time)
     300 Seconds (1 time)
Amp
Amp
Amp
Amp
350 / 400
525 / 710
390 / 510
350 / 400
 Starter Carry – Inrush 250 ms (10 repeats 1/ 2/) Amp NA / 2,000
 Starter Carry - Cranking 10 sec (10 repeats 1/ 2/) Amp NA / 500
 Maximum terminal Temp, Continuous Deg C 175
 Maximum terminal Temp, Intermittent Deg C 225
1/ Assumes UL508 ratings with 400 KCmil cables, ambient max. UL508 temperature of 75°C, and max. UL508 terminal temperature rise of 50°C. Contactor can also carry the higher currents shown on page 2 at 50°C ambient, and meet all of the UL508 requirements.
 
Contactor meets all of its published specifications at 85°C ambient, but terminal temperature can rise 60°C, which is higher than the 50°C allowed by UL508.
 
The maximum terminal temperature rating is 175°C, which means much higher currents than shown on page 2 can be carried and switched. However, this temperature is much higher than most cable insulation ratings, which mean busbars must be used. Contact ECPC for assistance for higher current applications.

 
2/ Rating consists of combined inrush + cranking current at the times specified, with 2 seconds off between cycles. This is higher current than is required for UL1107 for marine battery switches.
      
OPTIONAL  HIGH  EFFICIENCY  DUAL-COIL  RATINGS
 Coil Voltage (Nominal) 12Vdc 24Vdc 48Vdc
 Coil P/N Designation B C F
 Coil Voltage (Max) 1/ 15 30 60
 In-Rush Current Max (75 ms) – Amps 2/ 3/ 4.0 1.7 0.9
 Hold Current after in-rush (Avg.) - Amps 3/ 0.30 0.12 0.06
 Hold Power after in-rush (Avg.) – Watts 3/ 3.6 3.0 2.9
 Pick-up, Volts, Max 2/ 4/ 5/ 7.5 15.0 40
 Hold, Volts, Min 5/ 5.0 10.0 22
 Drop-Out, Volts, Min 5/ 0.5 2.0 2
 Coil Back EMF (volts) 6/ 45 45 110
Ratings are at 25ºC. For specific values at other temperatures, please contact ECPC.

1/ Because the contactor is operated by a coil that changes resistance with temperature, the maximum coil voltage will be lower than indicated at temperatures above 25C, and higher than indicated at temperatures below 25C.

2/ Contactor has two coils. Both are used for pull-in, and then in approximately 75 milliseconds, one coil is electronically removed from the coil drive circuit. The remaining coil supplies low continuous hold power sufficient for the contactor to meet all of its specified performance specifications. This provides the lowest coil power possible without the use of PWM electronics that have been known to cause EMI emissions and/or cross-talk on your system control power.

3/ Because the contactor is operated by a coil that changes resistance with temperature, and because Nominal Coil voltage has been assumed for the In-Rush, Hold Current and Hold Power specifications, Current/Wattage will be lower than indicated at temperatures above 25C and higher than indicated at temperatures below 25C.

4/ For Pick-up testing of contactors with dual coils, the voltage can not be ramped up slowly, but must be applied instantly to at least the maximum pull-in voltage or current. Otherwise, the contactor will not pick-up.

5/ Because the contactor is operated by a coil that changes resistance with temperature, Pick-up Voltage, Hold Voltage, and Drop Out Voltage will be lower than indicated at temperatures below 25C and higher than indicated at temperatures above 25C.

6/ These DC coils have built-in coil suppression. The use of additional external coil suppression can slow the release time and invalidate the life cycle ratings, or can cause the contactor not to be able to interrupt the maximum current specified. If lower coil back EMF is required, please contact ECPC for assistance.

 

  
High Voltage Relay Specifications
 Specifications Units Specifications
 Contact Arrangement (main) Form X SPST-NO
 Contact Arrangement (Auxilary) 1/ Form A SPST-NO
 Mechanical Life cycles 1 million
 Contact Resistance
     Max @ rated carry current
     Typical @ rated carry current
 
mohms
mohms
 
.4
.15 to .3
 Operate time, 25°C
     Close (includes bounce) Max
     Close (includes bounce) Typical
     Bounce on close, Max
 Release time (includes arc time at max. break current)
 
ms
ms
ms
ms
 
20
13
7
12
 Insulation Resistance Mohms 100 2/
 Dielectric at sea level (leakage < 1mA) VRMS 2,500
 Shock G’s peak 20
 Vibration, Sinusoidal (500-2000 Hz peak) G’s 15
 Operating ambient Temp Range °C -55 to +85 3/
 Storage ambient Temp Range °C -70 to +175
 Weight, Typical Kg (Lb) 0.44/(0.98)
1/ Auxillary contact rating - 2A, 24Vdc Resistive load, 100,000 cycles. Minimum current is 1mA, 5V. The auxiliary contact is mechanically linked to the main power contacts.
 

2/ 50 Mohms after life.

3/ Contactor can operate up to 125°C in special cases - contact ECPC for details.

Contactor Part Number System
GX23 B C  B

 Coil Voltage
 B = 12 Vdc, internal coil suppression
 C = 24 Vdc, internal coil suppression
 F = 48 Vdc, internal coil suppression

 Coil Termination 
 A
= Flying leads, 38 cm (15 in)
 B = Flying leads, 61 cm (24 in)
 C = Flying leads, 122 cm (48 in)
 Auxiliary Contact (same length as coil wire selection)
 Blank
= None
 B = SPST, Normally Open

 


gx 200 gigavac contactor


To Lift and Remove the Terminal Safety Cover:


A.
Push the tab of the cover to unlock it.
B. Lift the cover as shown. It will pivot on the rear pin.
C. If needed, remove the cover by pulling it straight back as shown.
D. To place the cover back in its original position, replace the cover as shown. Follow step C in reverse.
E. The cover can now pivot down to close.
F. Make sure to push the locking tab into place.


Application Information:

WARNING - When using more than one lug on a power terminal, make sure the primary power is closest to the contactor busbar, with the lower current lug on top, then the washer, then the lock washer, then the nut. Improper order can cause severe over-heating resulting in the possible melting of the connecting cable insulation.
The use and the manner of use of controller products shall be the responsibility of the customer. The customer covenants and agrees to indemnify and save harmless ECPC in respect to any loss or damage that may arise through the use by the customer or others, of any of ECPC’s products.
 
 
6 Month Manufacturers Warranty!
 

* SHIPPING/PAYMENT OPTIONS *

There are two ways to get an exact quote for base shipping for your order. 1. Contact us at (801) 449-0681 10:30am-4pm Monday-Friday or [email protected] 2. Place your order by adding your items to the cart and then clicking "Proceed to Checkout".

  • Enter your phone number, email, physical address, and password
  • Select the “Shipping Method” of preference
  • Confirm the “Choose one payment method” has “Shipping Quote Request” selected
  • Click the “Check Out” button
  • You’ll receive a confirmation email of your request
We’ll research the exact shipping cost and send you an invoice to your PayPal.

Quantity discounts show in the cart

We love to meet or beat any competitor’s price!

Higher volume discounts, price matching or questions? Contact Carl, our resident specialist.
9am-9pm Mon-Sat MDT
(801) 449-0681
or email
[email protected]

Related Items
60VDC 100A to 144VDC 30A <br> PART#: 100D <br> 12V DC Contactor Set
60VDC 100A to 144VDC 30A
PART#: 100D
12V DC Contactor Set
Your Price: $31.00
EC-400D <br>  60 to 156V DC 400-500A Contactor <br> With Magnetic Blowouts <br> 12V DC Coil
EC-400D